Products » Level Sensors » Flowline EchoPod UG06 & UG12 Reflective Ultrasonic Level Transmitters
Flowline EchoPod UG06 & UG12 Reflective Ultrasonic Level Transmitters
Accurate Level Measurement up to 39.3 ft
The Flowline EchoPod UG06 & UG12 are high-performance reflective ultrasonic level transmitters designed for continuous level measurement in tanks up to 39.3 feet (12 meters). Featuring a reliable 4-20 mA analog signal output and four programmable relays, these level transmitters provide flexible control for a variety of industrial applications, including tanks, day tanks, IBCs, and cooling towers. The UG06 & UG12 are optimized for non-foaming and highly vaporous liquids like chemicals, water, wastewater, and oil.
Built with Flowline’s proprietary Reflective Technology™, these transmitters ensure consistent and reliable measurement even in condensing environments. The WebCal® software enables easy configuration and testing, making these sensors adaptable to your needs, whether for alarm control, automatic fill, or empty functions.
-
Overview
-
Ordering Information
-
Specification
-
Literature
The Flowline EchoPod UG06 and UG12 Reflective Ultrasonic Level Transmitters are designed for reliable performance in condensing environments, offering precise level measurement for a variety of liquid handling applications. Their advanced Reflective Technology™ ensures accurate measurement even with condensation present.
Key Features:
- Available in 6m (19.6′) and 12m (39.3′) measurement ranges.
- Reflective Technology™ for reliable performance in condensing conditions.
- Corrosion-resistant PVDF transducer with IP68 PP enclosure.
- Fail-safe diagnostics with selectable signal fail-safe outputs.
- LCD display shows level in inches, meters, or percentage of span.
- Narrow 3” (7.6cm) beam width for applications in limited spaces.
- Windowed enclosure cap provides liquid-tight level indication.
- Configurable via push-button display or WebCal software.
- Automatic temperature compensation from -40°F to 176°F (-40°C to 80°C).
Ordering Information for Flowline EchoPod UG06 & UG12 Reflective Ultrasonic Level Transmitters
Model Number | Sensor Range | Process Mount | FOB USB Adapter |
---|---|---|---|
UG06-00-1-0 | 06 (6m/19.6 ft) | 0: 2″ NPT (UG06) / 3″ NPT (UG12) | 0: Without Fob |
UG06-00-1-1 | 06 (6m/19.6 ft) | 0: 2″ NPT (UG06) / 3″ NPT (UG12) | 1: With Fob |
UG12-00-1-0 | 12 (12m/39.3 ft) | 2: 2″ G (UG06) / 3″ G (UG12) | 0: Without Fob |
UG12-00-1-1 | 12 (12m/39.3 ft) | 2: 2″ G (UG06) / 3″ G (UG12) | 1: With Fob |
Notes:
- If you need help selecting a sensor for your application, visit the website and submit a Level Questionnaire. An engineer will review your requirements and suggest a product solution via email.
- Install the sensor using Flowline installation fittings or equivalents.
- Sensors are available with or without the LI99-2001 FOB USB Adapter. The Fob can configure the sensor using WebCal software, and it can be used with any WebCal-compatible ultrasonic or guided wave sensor.
Specifications for Flowline EchoPod UG06 & UG12 Reflective Ultrasonic Level Transmitters
Description | Specification |
---|---|
Range | UG06: 8″ to 19.6′ (20cm to 6m) UG12: 18″ to 39.3′ (45.7cm to 12m) |
Accuracy | ± 0.2% of range |
Resolution | UG06: 0.079″ (2mm) UG12: 0.195″ (5mm) |
Dead band | UG06: 8″ (20.3cm) UG12: 18″ (45.7cm) |
Beam width | UG06: 3″ (7.6cm) UG12: 6″ (15.2cm) |
Configuration | Push button or WebCal® PC, Windows® USB 2.0 |
Memory | Non-volatile |
Display type | LCD, 6-digit |
Display units | Inch, cm, or percent |
Supply voltage | 14-28 VDC |
Max. consumption | 0.5W |
Loop resistance | 500 Ohms @ 24 VDC |
Signal output | 4-20mA, two-wire |
Signal invert | 4-20mA or 20-4mA |
Signal fail-safe | 4mA, 20mA, 21mA, 22mA, hold last |
Process temperature | F: -40° to 176° C: -40° to 80° |
Ambient temperature | F: -31° to 140° C: -35° to 60° |
Pressure | MWP = 30 PSI (2 bar) |
Enclosure rating | Type 6P (IP68), encapsulated, corrosion-resistant & submersible |
Enclosure material | Polypropylene |
Enclosure material for conduit | Polycarbonate with water-tight membrane |
Conduit entrance | 1/2″ NPT |
Transducer material | Polyvinylidene fluoride (PVDF) |
Process mount | 06-0011: 2″ NPT 06-0012: 2″ G 12-0011: 3″ NPT 12-0012: 3″ G |
Mount gasket | Viton® |
Classification | General purpose |
Approval | UL 61010-1 |
Compliance | CE, RoHS |