Flowline EchoPod UG06 & UG12 Reflective Ultrasonic Level Transmitters
Accurate Non-Contact Level Measurement for Tanks, IBCs, and Cooling Towers
The Flowline EchoPod UG06 and UG12 Reflective Ultrasonic Level Transmitters are high-performance sensors designed for continuous non-contact level measurement in tanks up to 39.3 feet (12 meters). Featuring a reliable 4-20 mA signal output and four programmable relays, these transmitters provide flexible control for industrial applications, including day tanks, IBCs, and cooling towers.
Optimized for challenging environments, the UG06 and UG12 utilize proprietary Reflective Technology™ to ensure consistent, reliable measurements in condensing and vaporous conditions. Built with a rugged, corrosion-resistant PVDF transducer and an IP68 enclosure, these transmitters offer long-lasting performance in industries like chemical processing, wastewater treatment, and oil refining.
With WebCal® software integration, the UG06 and UG12 can be easily configured for fail-safes, alarms, and pump control, making them ideal for applications requiring alarm control, automatic filling, or empty tank detection.
- Overview
-
Ordering Information
-
Specification
-
Applications
-
Literature
Overview of the Flowline EchoPod UG06 & UG12 Level Transmitters
The Flowline EchoPod UG06 & UG12 combine advanced sensing technology with a compact, durable design to deliver reliable level measurement for a wide range of liquids. With enhanced diagnostics and seamless configuration, these transmitters are ideal for industries requiring accuracy in complex environments.
Key Features:
- Measurement ranges of 19.6 feet (6 meters) and 39.3 feet (12 meters).
- Reflective Technology™ for reliable performance in vaporous or condensing environments.
- Corrosion-resistant PVDF transducer with a robust IP68-rated enclosure.
- LCD display for real-time level readings in inches, meters, or percentage of span.
- Narrow 3-inch (7.6 cm) beam width for installation in limited spaces.
- Fail-safe diagnostics with selectable signal outputs for alarm and pump control.
- Configurable via push-button display or WebCal® software for easy setup.
- Automatic temperature compensation from -40°F to 176°F (-40°C to 80°C).
Ordering Information for Flowline EchoPod UG06 & UG12
Model Number | Sensor Range | Process Mount | FOB USB Adapter |
---|---|---|---|
UG06-00-1-0 | 06 (6m/19.6 ft) | 0: 2″ NPT (UG06) / 3″ NPT (UG12) | 0: Without Fob |
UG06-00-1-1 | 06 (6m/19.6 ft) | 0: 2″ NPT (UG06) / 3″ NPT (UG12) | 1: With Fob |
UG12-00-1-0 | 12 (12m/39.3 ft) | 2: 2″ G (UG06) / 3″ G (UG12) | 0: Without Fob |
UG12-00-1-1 | 12 (12m/39.3 ft) | 2: 2″ G (UG06) / 3″ G (UG12) | 1: With Fob |
Notes:
- If you need help selecting a sensor for your application, visit the website and submit a Level Questionnaire. An engineer will review your requirements and suggest a product solution via email.
- Install the sensor using Flowline installation fittings or equivalents.
- Sensors are available with or without the LI99-2001 FOB USB Adapter. The Fob can configure the sensor using WebCal software, and it can be used with any WebCal-compatible ultrasonic or guided wave sensor.
Key Specifications of the Flowline EchoPod UG06 & UG12
Description | Specification |
---|---|
Range | UG06: 8″ to 19.6′ (20cm to 6m) UG12: 18″ to 39.3′ (45.7cm to 12m) |
Accuracy | ± 0.2% of range |
Resolution | UG06: 0.079″ (2mm) UG12: 0.195″ (5mm) |
Dead band | UG06: 8″ (20.3cm) UG12: 18″ (45.7cm) |
Beam width | UG06: 3″ (7.6cm) UG12: 6″ (15.2cm) |
Configuration | Push button or WebCal® PC, Windows® USB 2.0 |
Memory | Non-volatile |
Display type | LCD, 6-digit |
Display units | Inch, cm, or percent |
Supply voltage | 14-28 VDC |
Max. consumption | 0.5W |
Loop resistance | 500 Ohms @ 24 VDC |
Signal output | 4-20mA, two-wire |
Signal invert | 4-20mA or 20-4mA |
Signal fail-safe | 4mA, 20mA, 21mA, 22mA, hold last |
Process temperature | F: -40° to 176° C: -40° to 80° |
Ambient temperature | F: -31° to 140° C: -35° to 60° |
Pressure | MWP = 30 PSI (2 bar) |
Enclosure rating | Type 6P (IP68), encapsulated, corrosion-resistant & submersible |
Enclosure material | Polypropylene |
Enclosure material for conduit | Polycarbonate with water-tight membrane |
Conduit entrance | 1/2″ NPT |
Transducer material | Polyvinylidene fluoride (PVDF) |
Process mount | 06-0011: 2″ NPT 06-0012: 2″ G 12-0011: 3″ NPT 12-0012: 3″ G |
Mount gasket | Viton® |
Classification | General purpose |
Approval | UL 61010-1 |
Compliance | CE, RoHS |
Applications of the Flowline EchoPod UG06 & UG12
The Flowline EchoPod UG06 and UG12 are designed for diverse industrial applications, providing reliable and accurate level measurement for:
Bulk Tanks
Accurately monitors liquid levels in large storage tanks for industrial and chemical applications.
Day Tanks and IBCs
Ideal for compact day tanks and intermediate bulk containers, ensuring precise level control.
Cooling Towers
Handles high-humidity and vaporous conditions, delivering consistent level readings.
Chemical Storage
Reliably measures corrosive liquids in chemical processing facilities.
Wastewater Sumps
Monitors levels in wastewater treatment systems with challenging environmental conditions.
For more detailed information or to discuss your specific application needs, contact our sales team at sales@cannonindustrialplastics.com.