Products » Immersion Heat Exchangers » Niche Minicoil FEP and Q-Series Heat Exchangers
Niche Minicoil FEP Heat Exchangers
Niche Minicoil Heat Exchangers for Small Metal Finishing Baths
Niche Minicoil FEP and Q-Series Heat Exchangers are crafted from durable fluorocarbon resins, offering unmatched chemical resistance in small metal finishing baths where corrosion and fouling are constant issues. These heat exchangers resist scale buildup, ensuring smooth operation in demanding environments. The non-stick characteristics of fluoropolymers allow for minimal maintenance, while their inherent high electrical resistance helps prevent short circuits and stray currents, keeping plating baths safer. With 12 specifically designed models, the Minicoil series delivers efficiency, reliability, and safety in plating bath applications.
-
Overview
-
Ordering Information
-
Operation Limits
Key Features of Niche Minicoil FEP and Q-Series Heat Exchangers
The Minicoil FEP and Q-Series Heat Exchangers are specifically designed to improve efficiency and reduce costs in plating bath applications. These heat exchangers are built to resist corrosion, minimize fouling, and offer durable performance across a wide range of conditions.
- Cost-Effective: Significantly reduces operating and maintenance costs due to its durable and corrosion-resistant design.
- Anti-Fouling & Scaling: Prevents fouling or scaling, ensuring optimal heat transfer efficiency over time.
- Versatile Tubing Options: Available in a variety of resin materials, including fluoropolymers for enhanced chemical resistance.
- Corrosion Resistance: Ideal for highly corrosive environments such as metal finishing and chemical processing.
- Extended Lifespan: Built with materials that withstand aggressive media, reducing the need for frequent replacements.
- Optimal Heat Transfer: Provides high heat transfer efficiency, which is crucial for maintaining the quality of the plating baths.
- Nonstick Properties: The chemically inert surface minimizes buildup, ensuring smooth operation even in the harshest environments.
Minicoil FEP and Q-Series Heat Exchangers
Nominal Size (in) | Tubes per Unit | Tube O.S. Diameter | Tube Wall Thickness |
---|---|---|---|
12 | 1 or 2 | 0.25 in (6.4 mm) | 0.025 in (0.64 mm) |
15 and 18 | 3 or 4 | 0.312 in (7.9 mm) | 0.025 in (0.64 mm) |
Heat Transfer Area
Size (in) | Number of Tubes | Area FT² | Area M² |
---|---|---|---|
12 | 1 | 2.1 | 0.195 |
12 | 2 | 4.2 | 0.39 |
15 | 3 | 4.5 | 0.42 |
15 | 4 | 6.0 | 0.56 |
18 | 3 | 7.5 | 0.70 |
18 | 4 | 10.0 | 0.93 |
Model Number Configuration
Example: 12 F 1 | Description |
---|---|
12 | Nominal Frame Size – 12 inches |
F | Tubing Material – F for FEP, Q for Q-Tubing |
1 | Number of Tubes per Unit – 1 OR 2 for 12-inch models, 3 OR 4 for 15 and 18-inch models |
Operation Limits – Internal Pressure of Tubing
Maximum Temperature (°F) | Maximum Temperature (°C) | Maximum Pressure (psi) | Maximum Pressure (kPa) |
---|---|---|---|
50°F | 10°C | 160 psi | 1103 kPa |
100°F | 37.8°C | 140 psi | 965 kPa |
150°F | 65.6°C | 100 psi | 690 kPa |
200°F | 93.9°C | 60 psi | 414 kPa |
250°F | 121.1°C | 40 psi | 275 kPa |
300°F | 148.9°C | 20 psi | 138 kPa |