Niche Minicoil FEP Heat Exchangers

Niche Minicoil Heat Exchangers for Small Metal Finishing Baths

Niche Minicoil FEP and Q-Series Heat Exchangers are crafted from durable fluorocarbon resins, offering unmatched chemical resistance in small metal finishing baths where corrosion and fouling are constant issues. These heat exchangers resist scale buildup, ensuring smooth operation in demanding environments. The non-stick characteristics of fluoropolymers allow for minimal maintenance, while their inherent high electrical resistance helps prevent short circuits and stray currents, keeping plating baths safer. With 12 specifically designed models, the Minicoil series delivers efficiency, reliability, and safety in plating bath applications.

Niche Minicoil Fluoropolymer Heat Exchangers

Key Features of Niche Minicoil FEP and Q-Series Heat Exchangers

The Minicoil FEP and Q-Series Heat Exchangers are specifically designed to improve efficiency and reduce costs in plating bath applications. These heat exchangers are built to resist corrosion, minimize fouling, and offer durable performance across a wide range of conditions.

  • Cost-Effective: Significantly reduces operating and maintenance costs due to its durable and corrosion-resistant design.
  • Anti-Fouling & Scaling: Prevents fouling or scaling, ensuring optimal heat transfer efficiency over time.
  • Versatile Tubing Options: Available in a variety of resin materials, including fluoropolymers for enhanced chemical resistance.
  • Corrosion Resistance: Ideal for highly corrosive environments such as metal finishing and chemical processing.
  • Extended Lifespan: Built with materials that withstand aggressive media, reducing the need for frequent replacements.
  • Optimal Heat Transfer: Provides high heat transfer efficiency, which is crucial for maintaining the quality of the plating baths.
  • Nonstick Properties: The chemically inert surface minimizes buildup, ensuring smooth operation even in the harshest environments.

Minicoil FEP and Q-Series Heat Exchangers

Nominal Size (in) Tubes per Unit Tube O.S. Diameter Tube Wall Thickness
12 1 or 2 0.25 in (6.4 mm) 0.025 in (0.64 mm)
15 and 18 3 or 4 0.312 in (7.9 mm) 0.025 in (0.64 mm)

Heat Transfer Area

Size (in) Number of Tubes Area FT² Area M²
12 1 2.1 0.195
12 2 4.2 0.39
15 3 4.5 0.42
15 4 6.0 0.56
18 3 7.5 0.70
18 4 10.0 0.93

Model Number Configuration

Example: 12 F 1 Description
12 Nominal Frame Size – 12 inches
F Tubing Material – F for FEP, Q for Q-Tubing
1 Number of Tubes per Unit – 1 OR 2 for 12-inch models, 3 OR 4 for 15 and 18-inch models

Operation Limits – Internal Pressure of Tubing

Maximum Temperature (°F) Maximum Temperature (°C) Maximum Pressure (psi) Maximum Pressure (kPa)
50°F 10°C 160 psi 1103 kPa
100°F 37.8°C 140 psi 965 kPa
150°F 65.6°C 100 psi 690 kPa
200°F 93.9°C 60 psi 414 kPa
250°F 121.1°C 40 psi 275 kPa
300°F 148.9°C 20 psi 138 kPa